BENZ Packaging The Complete
Packaging Company

Compact corrosion inhibitor · Tablet format

BENZPACK™VCI Tablets

Compact VCI tablets for corrosion protection inside closed component packs and restricted spaces. Their solid format adds an inhibitor source where a larger wrap or emitter may be difficult to place.

BENZ VCI tablets beside an open product carton

BENZPACK™VCI Tablets material standards

Technical records connect product selection with the intended process and exposure.

Product specification

Select the material and format against the component, surface condition and documented product data.

Handling information

Use the current technical data and safety information for storage, installation and the production process.

Application support

Agree preparation, placement or application, exposure conditions and inspection criteria for the complete system.

Request the current TDS, SDS and applicable product records for your requirement.

Working principle

How VCI Tablets works.

VCI tablets release corrosion-inhibiting molecules into the air around enclosed metal parts. Select the tablet format, quantity and position for the internal volume and component layout. Their compact shape supports drop-in use, with placement and removal instructions included in the packaging process.

  1. Define the protected space

    Identify the metals, enclosure volume and internal compartments before selecting the tablet format.

  2. Place the tablets

    Position the selected quantity where vapour can reach the components while respecting the product's contact and retention instructions.

  3. Close and document

    Close the package and record tablet quantity, location and any required removal before the parts are used.

BENZPACK™VCI Tablets application examples

Explore component-specific packing examples, materials and placement.

BENZPACK™VCI Tablets industry applications

Single VCI tablet placed in the base of an open industrial instrument enclosure

Instrumentation

Retained tablets in compatible instrument housings

VCI tablets retained in holders inside an open electrical enclosure

Electrical equipment

Tablet holders within closed enclosures

Industrial spare parts components and packing environment

Industrial spare parts

Defined placement in component and service kits

BENZPACK™VCI Tablets technical specifications

Review the published values alongside the current specification for the selected grade.

Selection fieldProduct and application requirements
Product formSolid corrosion-inhibitor tablet; confirm the supplied grade, dimensions and unit mass.
Metal compatibilityMatch the formulation to every metal, plating and surface treatment in the assembly.
Quantity and enclosed volumeUse grade-specific dosing guidance for the actual enclosure, its partitions and leakage.
Retention and placementSelect a suitable holder or packing position that keeps the tablet secure without obstructing vapour release.
Operating conditionsConfirm the applicable temperature, humidity and enclosure-opening conditions.
Service and replacementAgree the replacement interval and inspection procedure for the selected application.
Storage and traceabilityConfirm shelf life, sealed-storage instructions and batch identification.
Published tablet dimensional reference
ParameterValue
Weight (g)1,5
Diameter (mm)18
Height (mm)7

These dimensions describe the published 1.5 g reference. The selected order specification identifies the supplied tablet format and its enclosure coverage.

VCI tablets retained in holders inside an open electrical enclosure

BENZPACK™VCI Tablets product documents

Request the current specification and supporting documents for your selected product and intended use.

Frequently asked questions

May a tablet be left loose in an enclosure?

Use a retained arrangement appropriate to the equipment and selected grade. A loose tablet can move, contact sensitive parts or be missed during service.

Do tablets provide ESD protection?

VCI describes corrosion-inhibiting function. Verify electrostatic properties separately if the application needs an ESD-control material.

How should tablet locations be documented?

Mark each location in the packing or maintenance record and include retrieval, inspection or replacement in the opening procedure.

Does the tablet need to touch the metal?

VCI is used to deliver inhibitor through the enclosed atmosphere. Follow the selected grade’s placement instructions and check direct-contact compatibility wherever a tablet or holder could touch the component.

Where are VCI tablets useful?

VCI tablets provide compact drop-in corrosion protection for closed packs and restricted spaces around metal components.

How do VCI tablets work?

The tablet releases corrosion-inhibiting molecules into the enclosed air space to support protection of accessible metal surfaces.

How is the tablet format selected?

Select the tablet format and quantity against the enclosure volume, metal, internal geometry and required protection period.

Can tablets protect a ventilated space?

They are intended for enclosed applications that retain VCI vapour. Air exchange and access frequency are important inputs to the packaging design.

What should I provide for a tablet recommendation?

Provide the enclosure dimensions, metals, surface condition, shipment or storage conditions and any placement constraints.

Product guidance

Related products and technical guidance.

Discuss BENZPACK™VCI Tablets requirements

Share the component, surface condition, process and exposure period to review the appropriate product and application.

Discuss your application →
Single VCI tablet placed in the base of an open industrial instrument enclosure
benz packaging solutions
Inquire Now

BENZ Packaging consistently provides reliable and efficacious Corrosion Prevention & Protective Packaging Solutions to clients worldwide.

benz packaging solutions